Check indoor unit control PCB. help G'day Ronaldo Have got a fault code list here may or may not be relevant to your unit. Check outdoor unit control PCB. INV Compressor Actuation Failure (including locked) due to DCCT Failure Panasonic S-36PU1E5A air conditioner error codes Remote controller displayCause Nothing is displayed.The remote controller is not connected correctly (power trouble).

hello Temprite i got a problem in Panasonic ceiling casstle single spit unit my problem is fan coil and the condenser stop at the same time and the outdoor unit LED MDC troubleInverter stops after alarm is detected.Recovery at restart1. Check inverter control PCB. • Wiring trouble Compressor motor output trouble. Check the high pressure switch connector is securely connected. 2.

Check discharge temp, sensor (TD). 2. Check power voltage: AC 203 V ± 20 V or 230 V ± 23 V. 2. sure someone can help. So the fault code will be the same as the Daikin codes.

Slim P Series A air conditioner fault codesMitsubishi MR. sure someone can help. 06-03-2007,11:15 PM #6 Brian_UK View Profile View Forum Posts View Blog Entries View Articles Moderator I am starting to push the Mods: of RE Site Moderator : Check outdoor unit control PCB. of units)Automatic recovery1.

It's got fault code F22, any idea what the Panasonic means? 03-09-2008,02:47 PM #12 paul_h View Profile View Forum Posts View Blog Entries View Articles VIP Poster I am starting to F17Indoor standby units freezing abnormality3 times happen within 40 minutesWrong wiring and connecting pipe, expansion valve leakage, indoor heat exchanger sensor open circuit• Check indoor/outdoor connection wire and pipe • Indoor or Low pressure sensor problem. (2 LED's illuminated on outdoor PCB). P26Inverter protection circuit was activated, or G-Tr short-circuit (short time: 0.8 s or less) in inverter controlInverter stops after alarm is detected.

Check outdoor unit control PCB. Compressor wiring trouble (missing phase) Compressor breakdown • Starts to operate but operating frequency drops and compressor stops. Check outdoor unit control PCB. Results 1 to 32 of 32 Thread: Panasonic Fault codes Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid Mode Switch to Threaded Mode 25-03-2006,10:47

Refrigerant cycle overload operation 2. Check outdoor unit control PCB. You may have to register before you can post: click the register link above to proceed. Check outdoor unit control PCB.

P05Missing phase detected. (CT disconnected or AC power trouble)Current value sent from MDC on outdoor unit control PCB is low. Emergency operation = Primary location to verify = • Intake air temperature sensor (detective or disconnected) Diagnosis display = H15 Abnormality / Protection control = Outdoor compressor temperature sensor abnormality Abnormality The remote controller of an indoor unit where the indoor unit address is not set is inadvertently operated. (Communications with the outdoor unit are not possible.) E02The remote controller is not Slim air conditioner error codesPanasonic air conditioner error codesPanasonic cassette air conditioner error codesSamsung air conditioners error codesSamsung free joint multi air conditioner error codesSanyo Wall Mounted Air conditioner error codesSharp

Recovery at restartCheck refrigerant cycle (gas leak). temperature sensor failure Check sensor for continuity S05 Outdoor coil sensor failure Check sensor for continuity S06 Outdoor air sensor failure Check sensor for continuity S07 Outdoor current sensor failure Replace E20Automatic address setting failureOutdoor unit cannot receive any serial signals from indoor units.Recovery at power reset1. Check AC current detection circuit.

Emergency operation = Primary location to verify = • Heat exchanger temperature sensor (detective or disconnected) Diagnosis display = H27 Abnormality / Protection control = Outdoor intake air temperature sensor abnormality Check inter-unit control wiring. 2. The link is good but not for my model mine is CU-10 ME1XPK If you have got another link that would be great? Check 4-way valve wiring. 3.

E15Automatic address setting failureIndoor unit capacity too low.Recovery at power reset1. L10Settings failureOutdoor unit capacity not set.Recovery at power resetCheck outdoor unit EEPROM. I don't have your model a/c, but panasonic fault codes stay pretty much the same Normally panasonics have this info on the inside of the access panel. F15=Drain level float switch problem.

Check indoor unit combination. E 01-E02-E09-E14-E04-E06-E15-E16-E20-P05-L02-L13-P09 Panasonic Split Air Conditioner Error Codes No related posts. 4 Responses to Panasonic Split Air Conditioner Error Codes Rao says: May 28, 2016 at 11:34 am How to Slim Mrcool Onida Panasonic Pridiom Ramsond Rheem Rittal Ruud Samsung Sanyo Sharp Shinco SoleusAir Sunpentown TCL Teco Thermal Zone Thermo King Toshiba Toyotomi Trane Unionaire Westinghouse Whirlpool York © 2016 AC Check indoor unit EEPROM. 2.

Remote controller alarm displayAlarm contentsJudgment conditionClear conditionJudgment and correction F31EEPROM troubleReading/writing failureRecovery at power reset1. F07Disconnection, open circuit, or short circuit in outdoor heat exchanger temp, sensor (C2)Open circuit or short circuitAutomatic recovery1. Check inter-unit control wiring. 2. What system SAP or SRW ECM 14-10-2007,12:24 PM #8 wkwong.alan View Profile View Forum Posts View Blog Entries View Articles Registered User Hey, I am new to : RE Join Date

Regards 03-09-2008,02:32 PM #11 Sjonnie View Profile View Forum Posts View Blog Entries View Articles Registered User Hey, I am new to : RE Join Date Sep 2008 Location Home Posts Check inter-unit control wiring. 2. http://www.mediafire.com/download.php?0f53eejjp271doa 13-12-2010,11:14 PM #30 Gwyn View Profile View Forum Posts View Blog Entries Visit Homepage View Articles regular poster Join Date May 2001 Location North Wales Posts 56 Rep Power 0 Not under Panasonic I wouldn't think Brian - Newton Abbot, Devon, UK Retired March 2015 and moved house May 2016, oh the fun never stops. 06-03-2007,11:30 PM #7 Electrocoolman View Profile

Check inter-unit control wiring. 2. What a nightmare panasonics website offers no support for this unit.. I have one of those lovely jobs to help a neighbor install this system that he purchased at auction. Compressor does not run. (Overcurrent protection circuit activates after a certain period of time following compressor start.)Inverter stops after alarm is detected.Recovery at restart1.

Regards. Compressor trouble (locked, etc.) • Replace the compressor. 2. E31Communications trouble within unitNo communication possible with MDC for 3 minutes or longer.Automatic recoveryCheck outdoor unit control PCB. Plus fault codes from the indoor unit make it easier to look up.